Loading...

Rct 10Kw On-Grid Inverter | RCT-INFINISOLAR 10K

R 48,442.00 R 42,123.48
Out of stock
SKU
RCT-INFINISOLAR 10K
  • Brands - Cliqtosave Online: RCT
  • 10KW 3-phase on-grid inverter with energy storage
  • Self-consumption and Feed-in to the grid
  • Programmable supply priority for PV, Battery or Grid
  • User-adjustable charging current up to 200A
  • Programmable multiple operations modes: Grid tie, Off grid, and grid-tie with backup
  • Built-in Timer for various mode of on/off operation
  • Multiple communication for USB, RS-232, Modbus and SNMP
  • Monitoring software for real time status display and control
More Information
BrandRCT
Supply TypeInverters

Details

Specifications and features
Product Code RCT-INFINISOLAR 10K
Model InfiniSolar 10KW
PHASE 3-phase in / 3-phase out
RATED OUTPUT POWER 10000 W
MAXIMUM CHARGING POWER 9600 W
PV INPUT (DC)
Maximum DC Power 14850W
Nominal DC Voltage / Maximum DC Voltage 720 VDC / 900 VDC
Start-up Voltage / Initial Feeding Voltage 320 VDC / 350 VDC
MPP Voltage Range 350 VDC ~ 850 VDC
Number of MPP Trackers / Maximum Input Current 2 / 2 x 18.6A
GRID OUTPUT (AC)
Nominal Output Voltage 230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range 184 - 265 VAC per phase
Nominal Output Current 14.5A per phase
Power Factor > 0.99
EFFICIENCY
Maximum Conversion Efficiency (DC/AC) > 96%
European Efficiency@ Vnominal > 95%
AC INPUT
AC Start-up Voltage/Auto Restart Voltage 120 - 140 VAC per phase / 180 VAC per phase
Acceptable Input Voltage Range 170 - 280 VAC per phase
Maximum AC Input Current 40A
PV INPUT (DC)
Maximum DC Voltage 900 VDC
MPP Voltage Range 350 VDC ~ 850 VDC
MNumber of MPP Trackers / Maximum Input Current 2 / 2 x 18.6A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage 230 VAC (P-N) / 400 VAC (P-P)
Output Waveform Pure Sinewave
Efficiency (DC to AC) 0.91
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage 720 VDC / 900 VDC
Start-up Voltage / Initial Feeding Voltage 320 VDC / 350 VDC
MPP Voltage Range 350 VDC ~ 850 VDC
Maximum Input Current 2 / 2 x 18.6A
GRID OUTPUT (AC)
Nominal Output Voltage 230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range 184 - 265 VAC per phase
Nominal Output Current 14.5A per phase
AC INPUT
AC Start-up Voltage/Auto Restart Voltage 120 - 140 VAC per phase / 180 VAC per phase
Acceptable Input Voltage Range 170 - 280 VAC per phase
Maximum AC Input Current 40A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage 230 VAC (P-N) / 400 VAC (P-P)
Efficiency (DC to AC) 0.91
BATTERY & CHARGER
Nominal DC Voltage 48 VDC
Maximum Charging Current Default 60A, 10A - 200A (Adjustable)
PHYSICAL
Dimension, D x W x H (mm) 622 x 500 x 167.5
Net Weight (kgs) 45
INTERFACE
Communication Port RS-232/USB and CAN Interface
Intelligent Slot Optional SNMP, Modbus, and AS-400 cards available
ENVIRONMENT
Humidity 0 ~ 90% RH (No condensing)
Operating Temperature -10 to 55°C
Altitude 0 ~ 1000 m

Questions (0)

Reviews

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
What's this? Check "Remember Me" to access your shopping cart on this computer even if you are not signed in.